Executable intermediate representation

TwinForge lowers resolved controller logic into a typed, vendor-neutral executable intermediate representation before selecting a PLCopen target. This prevents CODESYS conventions from becoming assumptions for OpenPLC or other IEC runtimes.

Boundary

Captured source
    |
    v
Lossless syntax
    |
    v
Resolved semantics
    |
    v
Executable IR
    |
    +--> canonical IEC Structured Text emitter
    +--> CODESYS PLCopen adapter
    +--> future OpenPLC adapter

The IR currently represents:

  • typed references and literals;
  • unary and binary expressions;
  • validated member, array and dynamic-bit access;
  • classified calls and target-adapter requirements;
  • array-dimension queries;
  • assignments and effectful calls;
  • IF branches, WHILE loops and EXIT;
  • reusable-unit parameters, local variables and routines;
  • unsupported expressions and statements with their original source spans;
  • lowering and interface-effect diagnostics.

The source syntax document and routine text remain unchanged. Lowering does not authorize a target exporter to omit unsupported nodes.

Str_Capacity proof

The captured Rockwell instruction:

SIZE(Ref_Data, 0, Val);

lowers to the neutral operation:

Val := array_dimension(Ref_Data, 0)

This is represented structurally as an assignment containing an IRArrayDimension; it is not stored as generated target text.

The captured AOI declares Val with Usage="Input" even though the implementation writes it. The IR preserves that interface and emits a write_to_input_parameter diagnostic. A later target transformation must explicitly preserve or redesign this effect instead of silently changing the interface.

Str_Capacity is currently classified as a function candidate because it has no retained local tags or lifecycle routines. This classification is an implementation-shape recommendation, not proof that its captured interface is already valid for every IEC target.

Explicit interface normalization

Interface normalization is a separate, opt-in IR transformation. Its default preserve policy returns the original immutable unit without changes. The promote_written_inputs policy may be selected when an IEC-compatible interface is required:

  • an input proven to be an assignment target is promoted to an output;
  • a function candidate requiring that multi-direction interface is promoted to a function block;
  • each change is recorded as an IR diagnostic;
  • the original captured IR and L5X source remain unchanged.

For Str_Capacity, this promotes Val to VAR_OUTPUT and records input_promoted_to_output and unit_promoted_to_function_block. This is an explicit interoperability decision, not a reinterpretation of the captured Rockwell declaration.

AOI execution semantics

Rockwell AOI enable behavior is applied as a separate target-neutral transformation after interface normalization:

  • EnableOut receives the default state of EnableIn;
  • the primary Logic routine executes only while EnableIn is true;
  • source logic inside the primary routine may subsequently override EnableOut;
  • disabled Prescan, Postscan, and EnableInFalse flags remain captured but do not generate executable calls;
  • an enabled lifecycle mode without a mapped captured routine makes emission incomplete.

For Str_Capacity, whose three optional lifecycle flags are false, the transformed body is:

EnableOut := EnableIn;
IF EnableIn THEN
    Val := array_dimension(Ref_Data, 0);
END_IF;

The transformation is auditable and idempotent. It records default_enable_out_synthesized, main_routine_guarded_by_enable_in, and aoi_enable_semantics_applied.

Rockwell represents optional lifecycle logic with a separate ScanModeRoutine container. TwinForge captures those routines separately from primary logic and lowers the documented names to explicit IR roles:

Captured name IR role
Prescan prescan
Postscan postscan
EnableInFalse enable_in_false

Unknown scan-mode names remain unknown_lifecycle and block complete emission. An enabled EnableInFalse routine is mapped into the normal enable-guard's false branch. Disabled lifecycle routines remain retained in IR but are excluded from emitted normal logic.

Prescan and Postscan require target startup/shutdown semantics and therefore remain explicit blocking requirements when enabled. Their source is never concatenated into the cyclic function-block body.

Observed Studio 5000 v35 exports can also place a lifecycle-named routine, such as Prescan, inside the ordinary <Routines> container. TwinForge retains that captured container placement but assigns the execution role from the documented routine name. It emits an informational lifecycle_routine_in_routines_container diagnostic so the source-layout variation remains visible.

For CODESYS, an explicit FB_Init method is the leading Prescan adapter candidate. CODESYS calls this hook during function-block initialization and requires the bInitRetains and bInCopyCode inputs. Its online-change behavior is not identical to a Rockwell prescan event.

The native 11_fb_init.xml evidence confirms that CODESYS nests an FB_Init Method inside the function block's application-extension addData. TwinForge now emits enabled captured Prescan logic there, followed by FB_Init := TRUE;, and includes the mandatory Boolean inputs bInitRetains and bInCopyCode. It deliberately does not condition the source Prescan logic on either target input because the Rockwell source contains no corresponding condition.

This is an explicit CODESYS adapter, not a neutral IR assumption. Cold-start, warm-start, online-change, and Program-to-Run equivalence still require runtime tests. Declaration initializers are not used as a general substitute for arbitrary Prescan logic. See the official CODESYS documentation for FB_Init, FB_Reinit, and FB_Exit.

Wall-clock reads are also explicit neutral IR statements. The operation records the destination and timestamp unit; it does not retain a generic opaque GSV call. For the observed Rockwell GSV(WallClockTime, ..., CurrentValue, ...) service, that unit is microseconds.

The CODESYS adapter maps the operation to SysTimeRtcHighResGet, adds target-only SysTime and SysTypes.RTS_IEC_RESULT state, and converts the returned UTC milliseconds to microseconds. This preserves the source arithmetic rather than rewriting unrelated expressions. Logic following the read is guarded by the result code. On failure, ordinary Boolean output parameters are forced false so stale time is not presented as a valid pulse. The required SysTimeRtc, SysTime, and SysTypes libraries are emitted only when the mapped capability is present.

Scalar AOI parameter defaults remain typed evidence in executable IR. When the example exporter integrates a function-block instance into PLC_PRG, it copies those defaults to the corresponding program-local variables. Generated binding names use IEC-style datatype prefixes (x, di, li, and so on), so a binding never relies on case alone to differ from its parameter. For example, Inp_Interval is bound to diInp_Interval, initialized to the captured value 1000.

The capture tests use tests/data/aoi/scan_mode_routines.L5X, a fixture derived from the structure documented in Rockwell publication 1756-RM014D-EN-P. It is labelled as specification-derived and is not presented as a Studio 5000 export. A native exported fixture should replace or supplement it when available.

Target-independent rules

  • Every IR node retains a source span.
  • Known expression types are copied from semantic analysis.
  • Unresolved references or accesses become unsupported IR expressions.
  • Unknown calls are never treated as portable calls.
  • A source-vendor call retains its vendor and an adapter_required marker.
  • Rockwell output-operand instructions may lower into neutral assignments only through explicit, tested rules.

The first such rule is SIZE(array, dimension, destination). Additional instruction rules will be added individually with semantic and target tests.

Canonical IEC Structured Text

The canonical IEC emitter consumes only executable IR. It renders portable operators and control flow directly, while emitting TwinForge intrinsics for neutral operations that require target support:

Intrinsic Target requirement
TF_ArrayDimension(array, dimension) array_dimension
TF_BitAt(value, bit) dynamic_bit_access
TF_<operation>(...) source_operation_adapter

Generic InOut arrays render as ARRAY[*] OF <type> and add the generic_array_interface requirement. A CODESYS or OpenPLC adapter must map each reported requirement or reject the output.

Without normalization, Str_Capacity emits:

FUNCTION_BLOCK Str_Capacity
VAR_INPUT
    EnableIn : BOOL;
    Val : DINT;
END_VAR
VAR_OUTPUT
    EnableOut : BOOL;
END_VAR
VAR_IN_OUT
    Ref_Data : ARRAY[*] OF SINT;
END_VAR
Val := TF_ArrayDimension(Ref_Data, 0);
END_FUNCTION_BLOCK

The emission is intentionally marked incomplete because Val is a captured input that the body writes. The use of a function block rather than the IR's function-candidate recommendation is also reported. No target import should be described as successful until that interface effect and both target requirements have explicit mappings.

With promote_written_inputs, it emits:

FUNCTION_BLOCK Str_Capacity
VAR_INPUT
    EnableIn : BOOL;
END_VAR
VAR_OUTPUT
    EnableOut : BOOL;
    Val : DINT;
END_VAR
VAR_IN_OUT
    Ref_Data : ARRAY[*] OF SINT;
END_VAR
Val := TF_ArrayDimension(Ref_Data, 0);
END_FUNCTION_BLOCK

That canonical emission is complete at the neutral IEC layer. It still reports array_dimension and generic_array_interface requirements, which a CODESYS or OpenPLC adapter must implement before claiming target-ready output.

CODESYS Structured Text adapter

The CODESYS adapter consumes the same executable IR and uses documented CODESYS constructs:

  • ARRAY[*] OF <type> remains a variable-length VAR_IN_OUT array;
  • a zero-based neutral array_dimension(array, n) becomes UPPER_BOUND(array, n + 1) - LOWER_BOUND(array, n + 1) + 1.

The + 1 on the dimension operand is intentional: Rockwell SIZE numbers its first dimension as zero, while CODESYS identifies the first dimension as one. Subtracting the lower bound is necessary because an IEC array does not have to begin at index zero.

After interface and AOI execution normalization, the Str_Capacity body becomes:

EnableOut := EnableIn;
IF EnableIn THEN
    Val := ((UPPER_BOUND(Ref_Data, (0 + 1))
        - LOWER_BOUND(Ref_Data, (0 + 1))) + 1);
END_IF;

Both target requirements are resolved by this adapter, so the resulting CODESYS ST emission has no unresolved requirements. The normalization diagnostics remain attached as an audit trail.

CODESYS PLCopen XML

CodesysIRPLCopenExporter packages the adapted ST and normalized interface as a CODESYS application-extension POU. Its variable-length array representation is based on the native CODESYS export reference/PLCopenXML/codesys-native/10_variable_array_size.xml.

CODESYS represents the VAR_IN_OUT declaration differently from the standard PLCopen interface lists:

<inputVars>
  <variable name="Ref_Data">
    <type>
      <pointer>
        <baseType><SINT /></baseType>
      </pointer>
    </type>
    <addData>
      <!-- CODESYS attributes retain the Inout scope, ARRAY[*] type and
           dimension count. -->
    </addData>
  </variable>
</inputVars>

TwinForge reproduces the native extension attributes, emits deterministic Application and POU object IDs, and retains IR diagnostics and unresolved requirements in CodesysPLCopenIRResult. CODESYS generic-array support is claimed only for function-block VAR_IN_OUT; other directions remain explicit unresolved requirements.

The PLCopen IR exporter always packages the reusable POU and can optionally consume an explicit CodesysProjectIntegration. That configuration adds:

  • a program POU such as PLC_PRG;
  • a function-block instance and typed local argument variables;
  • an ST function-block call with direction-correct := and => bindings;
  • a cyclic task and scheduled pouInstance; and
  • matching deterministic project-structure objects.

Generic arrays require an explicit fixed dimension at the call site. The exporter does not infer an actual array length from the AOI's ARRAY[*] interface.

Unsupported IR nodes emit visible TwinForge unsupported comments or TF_UNSUPPORTED() expressions and make the result incomplete. Units with multiple source routines also remain incomplete until their normal, prescan/postscan, or other lifecycle roles are mapped.